# Readiness probe

> Simple readiness check for container orchestration. Returns 200 if the
Brain is ready to serve requests (MQTT connected).




## OpenAPI

````yaml get /ready
openapi: 3.1.0
info:
  title: Aris API
  version: 1.0.0
  description: >
    REST API for controlling Aris home comfort systems.


    Aris is an air-to-water heat pump system that heats, cools, and provides hot
    water for homes.

    The Aris Brain is the central controller, managing zones, fan-coil units
    (FCUs), heat pumps,

    domestic hot water (DHW), and thermal energy storage (TES).


    ## Base URL


    The Aris Brain runs on your local network. Find your Brain's address via:

    - mDNS: `http://aris.local` (if your network supports mDNS)

    - Router admin panel: Look for a device named "aris-brain"


    ## Authentication


    Most API endpoints require authentication via Bearer token. Create an API
    token in the Aris web UI under **Settings → API Tokens**.


    Include the token in the `Authorization` header:

    ```

    Authorization: Bearer your-api-token

    ```


    ## Real-time Updates


    For real-time updates, connect to the WebSocket at
    `ws://aris.local?token=YOUR_API_TOKEN`.

    The WebSocket broadcasts zone state changes, system events, and device
    telemetry.
servers:
  - url: http://aris.local
    description: Local network (mDNS)
  - url: http://{brainIp}
    description: Local network (IP address)
    variables:
      brainIp:
        default: 192.168.1.100
        description: Your Aris Brain's IP address
security: []
tags:
  - name: Health
    description: Health check and readiness endpoints
  - name: System
    description: System-wide state and mode control
  - name: Zones
    description: Zone management, setpoints, and temperature control
  - name: DHW
    description: Domestic Hot Water tank status and history
  - name: TES
    description: Thermal Energy Storage tank status
  - name: HCU
    description: Hydronic Control Unit status
  - name: Heat Pumps
    description: Heat pump telemetry and diagnostics
  - name: FCUs
    description: Fan Coil Unit telemetry and status
  - name: Weather
    description: Weather data and forecasts
  - name: Events
    description: System event log and audit trail
  - name: Metrics
    description: VictoriaMetrics time-series data proxy
  - name: Prometheus
    description: Prometheus-compatible API for Grafana
  - name: Tokens
    description: API token management
  - name: Config
    description: System configuration (read-only)
  - name: Firmware
    description: FCU firmware OTA updates
paths:
  /ready:
    get:
      tags:
        - Health
      summary: Readiness probe
      description: |
        Simple readiness check for container orchestration. Returns 200 if the
        Brain is ready to serve requests (MQTT connected).
      operationId: getReady
      responses:
        '200':
          description: System is ready
          content:
            application/json:
              schema:
                type: object
                properties:
                  ready:
                    type: boolean
                    example: true
        '503':
          description: System is not ready
          content:
            application/json:
              schema:
                type: object
                properties:
                  ready:
                    type: boolean
                    example: false
                  reason:
                    type: string
                    example: MQTT broker not connected
      security: []

````